Hioki 3153 pdf
Articles Quick Answers Messages. Please be aware of what you are ordering before placing an order for the item. Fluorescent tube display digitalAnalog meter Monitor function: ReadLine ; if message.
I used the Writeline method of the SerialPort class. Pre-register for updates on hiiki this product will be available for ordering. Call back in 5 minutes 15 minutes 30 minutes 1 hour 1. This high technology instrument is designed for insulation resistance and voltage withstand testing of electrical devices and components according to various safety standards.
Download source code — Please login or register before adding a question. Rack up your Westside Dollars in the following ways: To ask our Hioki experts a question please include your contact details. Because, they will not work in remote mode. Output nAddress, onValue ; else PortAccess. Serial port RS is still used in industrial applications but has recently disappeared from most notebooks. Same as the power supply frequency Measurement range: The Namespace I use two different namespaces: A majority of the necessary parts and accessories from the Hioki catalog are listed on our website.
PQ - Download Access. Complete the below form to access downloadable materials. Component Testing. Get in contact with one of our Hioki Industry Experts! Let us know what you are interested in and one of our experts will get back to you. Battery Tester Trade-In.
Company Phone. Production Testing Equipment. Data Center Information. Page H. Do not touch when high voltage is applied. Connect to the HIGH terminal on the unit. Page Wearing Rubber Gloves Lead, etc. To avoid electrocution, always wear high-voltage protective rubber gloves when using this product. Contact your dealer or Hioki representative to help you look for high- voltage protective rubber gloves.
If an attempt is made to use an improper supply voltage, there is danger of damage to this unit and of life-threatening risk to the operator. Main power switch 2. The model name and version number are displayed as below: Software version Model name "Version 1.
Interface "RSC bps" is displayed. Page Connecting The H. Test Lead Hioki representative for repair. To avoid electric shock, make sure the H. Prepare a resistor with a resistance smaller than that of the calculation result from the output voltage and test upper-limit value breaking current that are preset in the withstand-voltage test.
Read chapter 2, and make the necessary preparations for testing. Press the key to enter withstand-voltage mode. The W lamp above the key to the left lights. Flashing Note that the output waveform may be distorted when conducting an AC withstand The lamp is turned on.
This indicates that a test is in TEST progress. If the measured-current value deviates from these values, the unit shifts to the FAIL state and the test is terminated. Saving and loading for setting data and the setting of optional functions are made following the READY state. If the output voltage fails to reach the test voltage within TEST approximately 5 seconds after completion of the ramp-up time, the unit will change to the FAIL state and the test will be terminated.
The frequency of the test voltage is 50 Hz. For AC withstand-voltage tests. The frequency of the test AC 60 Hz voltage is 60 Hz. Values currently set Values to be set Test-voltage value 1.
In this example, change the test time from s Press the key when is lit. Measured voltage value Upper-limit value The symbol appears when the upper-limit value is set, icon and Lower- and the symbol appears when the lower-limit value is limit value icon set.
Press the key to start a test. START flashes until the output voltage reaches the set test voltage. Press the key to enter insulation-resistance mode. The I lamp above the key to the left lights. If the measured resistance value deviates from either of these values once the test time has elapsed, the unit shifts to the FAIL state.
Test-voltage value: V 1. This is effective when a test object contains a capacity load. Delay time: 3. Values currently set Values to be set Test-voltage value V Press the keys, key. In this example, change the test time from START 2. A voltage is output until the test time elapses and the resistance is measured. A voltage continues to be output until the test time elapses and measure resistance.
This mode has two types: 1 W I mode Tests for withstand voltage, then insulation resistance. This indicates that a test is in progress.
You can make settings for each test type in a variety of modes. See chapter 3 and chapter 4 The settings for W I mode are the same as those for withstand-voltage mode. See Section 3. See chapter 3. Make insulation-resistance test settings in insulation-resistance mode.
See chapter 4. See Section 4. The lamp stays on during the test. The lamp will also light if a voltage exceeding the safety voltage approximately AC 0.
In such cases, the measured current value is not displayed correctly. When the optional "Insulation Resistance Measurement Range" Press the key to enter program mode.
The lamp above the key PROG lights. In the program setting state, is not lit, and the test cannot be started. When the key is pressed, the lamp lights up.
The step number flashes. Press the key to proceed to the next setting. Create a program for conducting a test in the following order and under the following conditions: Step 1. In this example, the file number shown is 1. Change the file number to using the keys. Test type: AC50 Hz Test-voltage value: 1. Test type: DC Test-voltage value: 2. LOAD 2. DANGER Make sure that no high voltage is being applied to the output, confirm the following items, and output voltage.
If the test object contains a capacity component, switching may take some time. To set an optional function, select the number assigned to the function except for output-voltage setting. The fixed ranges are automatically selected depending on the preset lower-limit value. Auto range switches between ranges depending on the measured value, but it takes time to display this value, since it is displayed after the range is switched.
To inactivate the hold function, press the key. If the PASS hold function is not selected, the test result is displayed for about 0. If the FAIL hold function is not selected, the test result is displayed for about 0. STOP To inactivate the hold function, press the key. In such a case, FAIL screening is performed or the test is terminated using the key. STOP Normally, pressing the key only starts the test.